PH41A Air Heaters - Gen III Air Heaters - Fuel System Priming
Issue Date: July 25, 2022 Scope: PH41A, 4kW Gen III Air Heater
Complaint:
On initial start up, the heaters require a priming phase Resolution: To improve start ability on initial start-up, the PH41A air heater has a fuel priming phase. Press and hold the “Start / Stop” button and hold for approximately 3 seconds. |
|
Upon hearing an audible beep and “POLR” appearing on the screen, release the “Start / Stop” button. The heater will now enter into a Fuel Priming mode. It will rapidly pulse 500 times then attempt a start up. If the system is sufficiently primed before this 500 pulse count is complete, simply press and hold the “Start / Stop” button to switch off the heater. This process can be repeated as necessary. To avoid flooding of the combustion chamber, this process should only be used when priming is required. |
Related Articles
PH21A - PHP Gen III Air Heater Maintenance Parts
Issue Date: Feb. 10, 2022 Scope: PHP Gen III, PH21A Complaint: What maintenance parts are required for my heater? Resolution: This Technical Bulletin provides a list of maintenance parts specific to the heater models listed. Maintenance Kit: Glow Pin ...
P25AG One-Way Fuel Check Valve
Issue Date: Feb. 6, 2024 Scope: P25AG, 2kw Gas Heater Complaint: The original manual did not show the One-Way Check Valve required for the fuel system. It is necessary to install this to ensure the fuel system will operate properly. Failure to ...
All Engine Heaters - Plumbing Guidelines
Issue Date: Feb. 24, 2021 Scope: All Engine Heaters Complaint: Heaters are experiencing coolant leaks. Resolution: It has been discovered that a prominent reason for coolant leaks is due to repeated overheating of the PHP heater resulting in damage ...
ESPAR 2kW - 4kW Air Heaters Maintenance
Issue Date: August 15, 2021 Scope: ESPAR 2kW - 4kW Air Heaters Complaint: Provide additional tools for customers to conduct their own ESPAR air heater maintenance. Resolution: This Technical Bulletin covers general, annual maintenance procedures ...
All Fuel Fired Heaters - Combustion Issues
Complaint: Heater will not start and provides a “No Start” fault code. Resolution: This is a guide to help technicians troubleshoot heater Combustion Issues. If the heater proceeds through a start up cycle but fails to establish a flame, runs ...